LAT 1000 Series: Time, Temperature and Depth Recorders for Birds
- Overview
- Features
- Specifications
- Photos
- Product Sheet
![]() LAT 1500 |
Gain valuable insights into the life cycle of your species.
Lotek Archival Tags are compact, reliable instruments for the collection and storage of time, temperature, and depth data.
The LAT series is the ideal data storage solution for any biologist seeking reliable long-term life-cycle-related data for fish, wildlife or avian species.
Available now: LAT1100, LAT1400, LAT1410 & LAT1500, LAT1800 (S,L), LAT 1900
- Five maximum pressure scales are available: 50m, 200m, 500m, 1000m, and 2000m.
- The LAT1410 uses two temperature sensors: the standard internal sensor and a second sensor mounted on a stalk to measure water temperature outside the body.
- LAT1100 is built as a flatpack for external attachment.
- Communications with the tags are highly reliable and fast (<2sec to connect) - now made through physical contacts.
- Enhanced biocompatibility from an inert coating.
- The LAT1500 features a sea water switch - this identifies when the tag is immersed in water.
- Tag design and components selection to ensure a typical two year life.
- Highly flexible in its programming with numerous configurable parameters, user selectable.
- Data ranges are configured by specifying the min. and max. limits for each sensor. Data resolution is determined by the number of bits (up to 12) assigned to each sensor. This optimizes the memory usage per sensor; selecting a lower resolution and/or narrow data range will increase the number of samples collected.
- Three memory
management (log type) options:
- Telescoping Log: allows the total times series storage capacity of the tag to be evenly distributed over the entire mission
- Conditional Log: samples recorded (or not) based upon the condition of one or two sampled “loggables”; and sample rate below a certain depth)
- Basic Log: straight sampling.
- The LAT 1900 (temperature + pressure datalogger) is only 2.1 g in air and features up to 26,000 data points and an optional radio beacon. Each data point includes temperature and pressure.
Time, temperature & depth LAT tags: (see below for LAT 1900)
| LAT1100 | LAT1400 | LAT1410 | LAT1500 | LAT1800S | LAT1800 L | |
| Tubular form factor: | ||||||
| Dimensions (mm) | 31.5 X 15 X 5.6 | 11 X 35 | 11 X 35 | 8 X 32 | 11 X 38 | 13 x 44 |
| Weight in air | 4.5 g | 5.1 g | 5 grams | 3.4g (estimate) | 6.3g | 11g |
| Weight in Fresh Water | ~ 1.7 grams | ~ 1.5 grams | ~ 2 grams | ~0.9g | TBD | |
| Flatpack form factor: | ||||||
| Dimensions (mm) | 36 x 11 x 7.2 | 36 x 13 x 10 | ||||
| Weight in air | 4.8g | 9g | ||||
| Weight in Fresh Water | TBD | |||||
| Memory | 64K, 128K | 64K, 128K | 128K | 128k, 512k | 128 Mbytes | |
| Memory Management | Custom Programming | Custom Programming | Custom Programming | Custom Programming | Custom Programming | |
| Survival Depth | 2000 meters | 2000 meters | 2000 meters | 2000 meters | 2000 meters | |
| Max Operation Temperature | 35° C | 35° C | 35° C | 35° C | 35°C | |
| Min Operation Temperature | -5° C | -5° C | -5° C | -5° C | -5° C | |
| Number of samples | Variable based upon data storage options selected | Variable based upon data storage options selected | Variable based upon data storage options selected | Variable based upon data storage options selected | variable based upon data storage options selected | |
| Sample rate setting | >1s in 1 sec. increments | >1s in 1 sec. increments | >1s in 1 sec. increments | >1s in 1 sec. increments | >1s in 1 sec. increments | |
| Data Download | Gold electrical contacts, 57.6 kbauds | Gold electrical contacts, 57.6 kbauds | Gold electrical contacts, 57.6 kbauds | Gold electrical contacts, 57.6 kbauds | Gold electrical contacts, 57.6 kbauds | |
| Sea water switch | Yes | Yes | Yes | Yes | Yes | |
| Standard Depth Range | 50m, 100m, 200m, 500m, 1000m | 50m, 100m, 200m, 500m, 1000m, 2000m | 50m, 100m, 200m, 500m, 1000m, 2000m | 50m, 100m, 200m, 500m, 1000m, 2000m | 50m, 100m, 200m, 500m, 1000m, 2000m | |
| Data Resolution | Up to 8 bit (64k version) or up to 12 bits (128k version) | Up to 8 bit (64k version) or up to 12 bits (128k version) | Up to 12 bits maximum | Up to 12 bits maximum | Up to 12 bits maximum | |
| Processing scale and offset | No | No | No | Yes | Yes | |
| Sensors | Internal Temperature, and Pressure | Internal Temperature, and Pressure | Internal & External Temperature, and Pressure | Internal Temperature, and Pressure | Internal Temperature, and Pressure | |
| Temperature Sensor Stalk | No | No | Yes | No | No | |
| Light sensor stalk | No | No | No | No | No | |
| Pressure Accuracy | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Pressure Resolution | 0.05% | 0.05% | 0.05% | 0.05% | 0.05% | |
| Temperature Measurement | -5° to 35° C | -5° to 35° C | -5° to 35° C | -5° to 35° C | -5° to 35° C | |
| Temperature Accuracy | Better than 0.2° C | Better than 0.2° C | Better than 0.2° C | Better than 0.2° C | Better than 0.2° C | |
| Temperature Resolution | 0.05° C or better | 0.05° C or better | 0.05° C or better | 0.05° C or better | 0.05° C or better | |
| User Setup | Miscellaneous ways to log data (see Key Features) | Miscellaneous ways to log data (see Key Features) | Miscellaneous ways to log data (see Key Features) | Miscellaneous ways to log data (see Key Features) | Miscellaneous ways to log data (see Key Features) | |
| Number of log structures allowed | 1 (64k version), 3 (128k version) |
1 (64k version), 3 (128k version) |
3 | 4 | 4 | |
| Minimum Life | 1 year | 1 year | 1 year | 1 year | 1 year | 2 year |
| Expected Life | TBD | TBD | TBD | TBD | TBD | |
| Data Analysis Software | Yes | Yes | Yes | Yes | Yes | |
| LAT 1900 | |
| Dimensions | 8 mm X 15 mm x 7 mm |
| Weight in air | 2.0 g |
| Logging memory | Up to 56 kbytes |
| Number of samples | Up to 26,000 data points |
| Survival depth | 1.5 x pressure sensor |
| Sample rate setting | >1s in 1 sec. increments |
| Data download | Gold electrical contacts, 115.2 kbaud |
| Standard depth range | Bird: 50m, 100m, 200m |
| Data resolution | Up to 12 bits |
| Minimum Life | 6 months* |
| Typical Life | TBD |
| Sensors | Internal Temperature, Pressure, Light, Sea Water Switch |
| External sensor stalk | No |
| Pressure Accuracy | +/-1% |
| Pressure Resolution | 0.05% |
| Temperature Measurement | -5° to 45° C |
| Temperature Accuracy | Better than 0.2° C (when within -5° to 35° C) |
| Temperature Resolution | 0.05° C or better |
| User Setup | Miscellaneous ways to log data (see Key Features) |
| Number of log structures allowed | 3 |
| Data Analysis Software | Available |
* at the sampling interval of every 12 seconds
For minimum life expectancy associated with sampling intervals less than this, please contact the appropriate Lotek account manager.
N.B. These specifications are subject to change.
![]() |
| LAT 1800 |
![]() |
| LAT 1100 |
![]() |
| LAT 1400 |
![]() |
| LAT 1410 |
![]() |
| LAT 1900 |